Welcome to Modern Instruments

Chinese

Tel:+86 13929571434

Product Details

Contact Us

  • Products*

  • Name*

  • Company*

  • Email*

  • Phone

  • Address

  • Message

  • Codes*

XD-21-862Xenon Test Chamber

Xenon Test Chamber

Product Number£º XD-21-862

Brand Name£ºMODERNER

Product Origin£º SHANGHAI

Purchasing Heat£º727

Standard£º ISO 11341, ISO 12040,ASTM G151,ASTM G155,ISO 4892-1,ISO 4892-2,SAE J2412£¬ISO 16474-1£¬ISO 16474-2 £¬ASTM D3451 £¬ASTM D3794£¬ASTM D4303£¬ASTM D5010£¬ASTM D6577£¬ASTM D6695£¬SAE J2527

It's the simplest, most reliable and easlest use weathering cabinet.

Click to see the big picture

Product Details

 ¢ñ. Introduction:

XD-21-862 is a multi-function big xenon light accelerated weathering testers which is equipped with one piece high power £¨6.5KW£©water-cooling xenon lamp, its exposure area arrive 6,500cm²

    
 

¢ò. Standards compliant£º

ISO 11341¡¶Paints and varnishes-Artificial weathering and expsure to artificial radiation—Exposure to filtered xenon-arc radiation¡·

ISO 12040¡¶Graphic Technology-Prints and Printing Inks - Assessment of Light Fastness Using Filtered Xenon Arc Light¡· 

ASTM G151¡¶Standard Practice for Exposing Nonmetallic Materials in Accelerated Test Devices that Use Laboratory Light Sources¡·

ASTM G155¡¶Practice for Operating Xenon Arc Light Apparatus for Exposure of Non-Metallic Materials¡·

ISO 4892-1¡¶Plastics - Methods of Exposure to Laboratory Light Sources - Part 1£ºGeneral guidance¡·

ISO 4892-2¡¶Plastics - Methods of Exposure to Laboratory Light Sources - Part 2£ºXenon-arc lamps¡·

SAE J2412¡¶Accelerated Exposure of Automotive Interior Trim Components Using a Controlled¡·

ISO 16474-1 ¡¶Paints and varnishes -- Methods of exposure to laboratory light sources -- Part 1: General guidance¡·

ISO 16474-2 ¡¶Paints and varnishes -- Methods of exposure to laboratory light sources -- Part 2: Xenon-arc lamps¡·

ASTM D3451 ¡¶Standard Guide for Testing Coating Powders and Powder Coatings¡·

ASTM D3794¡¶Standard Guide for Testing Coil Coatings¡·

ASTM D4303 ¡¶ Standard Test Methods for Lightfastness of Pigments Used in Artists' Paints¡·

ASTM D5010 ¡¶Standard Guide for Testing Printing Inks and Related Materials¡·

ASTM D6577 ¡¶Standard Guide for Testing Industrial Protective Coatings¡·

ASTM D6695 ¡¶Standard Practice for Xenon-Arc Exposures of Paint and Related Coatings¡·

SAE J2527 ¡¶Accelerated Exposure of Automotive Exterior Materials Using a Controlled Irradiance Xenon-Arc Apparatus¡·


¢ó. Features£º

Powerful functions and reliable test results

¡ô Meet with all international standards of xenon test.

¡ô Equipped with ATLAS xenon arc lamp , filter and components, ensure to get high and same running parameters. Test results have a good reliability and repeatability comparing with import machines.

¡ô Automatic rotating drum-type sample rack with three floors structure maximizes exposure uniformity over all specimens

¡ô 6,500cm2 exposure area , can hold different shapes and sizes samples.

¡ô Can set the cumulative energy £¨total irradiance energy£©obtained by sample to finish a test procedure. 

¡ô Advanced cooling system for xenon lamp and intelligent air system.

¡ô Chinese or English operation window 

Can set and control automatically many test parameters

¡ô Irradiance energy can be set and accurately controlled£¨340nm£¬420nm£¬300nm¡«400nm£¬300nm¡«800nm£©. The "Closed-Loop" control system can monitor and automatically compensate the change of light intensity caused by ageing or other factors.

¡ô Working room temperature, BPT£¨black panel temperature£©and BST£¨black standard temperature£©can be set and controlled automatically. With high precision Pt 100 temperature sensor, all these temperatures could be monitored accurately.

¡ô Working room relative humidity can be set and controlled automatically. With ultrasonic wave humidifying system, the working room can obtain more stable and uniform humidity distribution.

¡ô Can set spray way to sample£¨front spray or back spray£©, spray time and spray interval time.

Operation-Menu 

 

Simple, easy to use

¡ô Colorful touch screen and user-friendly operation interface allow operator to set the test parameters and monitor it easily.

¡ô The test procedures can be programmed freely; and up to 16 predetermined procedures can be saved in one time. Every procedure includes up to 10 segments setting data.

¡ô With USB interface, operator can export any test parameters with Excel format at any time, convenient to check XD-SUN’s running status at any time.

¡ô Pure£¨deionized£©water machine is optional. With high purity water, operator can get a more reliable testing result£¬Chamber has alarm function for monitoring water. 

Safe and reliable

¡ô Many alarm protections£ºBig irradiance difference, pure water conductivity is over limits, too high temperature of cooling water, too low flow rate of cooling water, over-temperature, heating problem£¬abnormal lamp power.  XD-SUN will stop running automatically and show the alarm information in the operation window. 

¡ô Can select TCP/IP Ethernet interface, the user can tele-control the machine through TCP/IP internet.

Convenient to help customers to solve all problems and do some necessary after service 


Working Room


¢ô.Main Technical Parameters£º

Type

XD-21-862

Xenon Lamp

6.5 KW water cooling long arc xenon lamp

Light Filter

Import originally from ATLAS,    can simulate indoor or outdoor sunshine spectrum

Exposure Area

6,500 cm2
£¨63-65 pcs standard samples of 15cm×7cm size£©

Monitoring Method to Irradiance

340nm¡¢420nm¡¢300nm~400nm¡¢300nm~800nm

Adjustable Irradiance

See Table A

Lifetime of lamps

2000 hours

Adjustable Range of Working room

RT~70¡æ£¨Dark£©

Adjustable Range of BPT

RT~110¡æ

Adjustable Range of BST

RT~120¡æ

Temperature Stability

±1¡æ

Temperature Uniformity

≤2¡æ

Temperature Deviation

≤±1¡æ

Adjustable Humidity

Light£º10%-75%    Dark£º10%-95%

Rotate speed of sample

1 r/min£¨circle as lamp centre£©

Spray Function

Can set spray continuous time and spray period

Water Demands

High purity deionized water£¨Conductivity<2us/cm£©

    Compressed Air

Clean£¬oilless compressed air with 0.5MPa pressure£¬Max. air supply is near 60L/min. Average air consumption is 10L/min¡«30L/min£¨Depends on testing standard£©

Flow of Deionized Water

0.2L/min£¨Add humidity or spray£©

Power Supply

AC380V±10%£¬Three-phase four-wire 50Hz£»
Max. Current 50A£¬Max. Power 9.5KW

Overall Size

1220mm×1200mm×1970mm£¨L×W×H£©

Net Weight

500KG

Structure

Cabinet Material

Working room is made up of high quality stainless steel £¨SUS316£©

Chamber Door

Simple door to left with filter window£»
silicon rubber seal the door edge

Sample Holder

Stainless steel material, its position in the chamber can be adjusted£¨up, middle or down£©,
Sample crack rotate around the centre of lamp

Controller

Siemens programmable controller.
 LCD touch-screen

Way of adding humidity

Add humidity by high pressure aerosol

Thermometer

Heat insulate type black standard thermometer
and black panel thermometer

Cooling System

Cooled by compressor and forced-air blast system

Security Protections And Error Protections

Xenon Lamp Protection

Over temperature of cooling water£¬
low flow of cooling water£¬abnormal of lamp power

Alarm Function

Big irradiance difference, over-temperature of BPT or BST or Working room, big error of humidity, spraying water shortage, pure water conductivity is over limits.Operator can set these values and downtime

Pure System Protect

Monitor the conductivity of pure water at real-time£¨Once the conductivity≥2us/cm, the machine will stop and alarm£©

Protection to Radiation

Xenon lamp will turn off automatically when opening the chamber door, in case xenon lamp radiate operator

Installing Environment Requirement

Site Requirement

Net area of installation site ≥12m2£»Net height≥2.8m.

Equipped with separate air condition which can ensure a 22¡æ¡«30¡æ & 30%¡«80% environment permanently.

No strong electromagnetic fields, no high concentration dust£¬no corrosive gas or flammable materials.                   

Power Source

380VÍÁ10%  3-phases£»50Hz£»50A power source£»Equipped with circuit£¬ground wire and air circuit breaker.

Air Outlet

 There should be air outlet£¨Distance to chamber ≤1.0m£¬height to ground is 2.5m¡«2.7m, diameter should be 153mm£©

Water Supply

Equipped with water supply pipes and valves£¬
Supply water pressure≥2.0kg/cm2£»conductivity≤120us/cm

Drainage

Draining pipes diameter≥ 50mm£¬
height to ground≤10cm£¬distance to chamber≤0.5m

 

 Table A£ºMain Configuration

Products

Numbers

Manufacture

Notes

Xenon Lamp

1 pc

USA brand

6.5KW£¨Also select other USA brand£©

Filter

1 set

USA brand

Includes five inner filters and one 4.5K/6.5K outer filter
£¨S BORO/S BORO£©

Control System

1 set

SIEMENS

S7-300 PLC+ Siemens analog imput

Interface

1 pc

 MCGS

10¨• human-computer touch screen

                          

Table B£ºAdjustable Range of Irridiance

 Combinating Filters

Adjustable Range of Irridiance£¨W/©O£©

Filters

Inner Filter

Outer Filter

Lamp Power£¨KW£©

340nm

420nm

300-400nm

Daylight

Type S Boro

Type S Boro

2.5¡«7.5

0.25¡«1.26

0.59¡«2.76

29¡«141

Window Glass

Type S Boro

Soda Lime

2.5¡«7.5

0.23¡«1.10

0.61¡«2.76

28¡«129

Extended UV

Quartz

Type S Boro

2.5¡«7.5

0.29¡«1.50

0.59¡«2.79

32¡«161

 

¢õ. Configuration list£º

Type

XD-21-862

Template frame

65

Blackboard temperature frame (including PT100)

2

ATLAS 6.5KW Xenon lamp

1

S BORO/ S BORO  (inner/outer filter)

1

aluminium plate

65

Irradiance correction frame

1

Instructions

1

XD 8140 Irradiance calibrator£¨optional£©

1£¨Optional parts£©

XD 8141 Irradiance calibrator£¨optional£©

1£¨Optional parts£©

XD 8142 Irradiance calibrator£¨optional£©

1£¨Optional parts£©

Deionized water system£¨optional£©

1£¨Optional parts£©

 

¢ö. Optional parts ordering information:

Type

Name

XD-21-862

Xenon Test Chamber

XD-8158

USA brand 6.5 kW Xenon Lamp £¨Water-cooled£©

XD-8159

6.5 kW Xenon Lamp Lamp imported from America £¨Water-cooled£©

XD-8160

USA brand 2000 HRS Supply PKG£¨Includes one BGD 8158 USA brand 6.5 kW water-cooled lamp£¬5pcs S65 inner filters£¬one pc 4.5K/6.5K outer filter£©

XD-8161

6.5KW BGD 2000 HRS Supply PKG£¨Includes one BGD 8159 USA brand 6.5 kW water-cooled lamp£¬5pcs W-143 inner filters£¬one pc W-144 outer filter£©

XD-8171

Purity Water System
£¨100L/h, pure water can less than 0.1µS/cm £¨input water£¼200µS/cm£©£©

XD-8176

Cooling Water Machine£¨For cooling and cycling pure water, can greatly reduce water consumption£© 

XD-8179

Air Compression System
£¨Includes air compressor¡¢air reservoir¡¢freezing dryer¡¢precise filter etc£©

XD-8186

Daylight Filter

XD-8187

Window Glass Filter

XD-8192

Metal Frame Air Filters

XD-8197

Sample shelf

 

¢÷. Documents:

Similar Products

Issued with In-House Calibration Certificate


Latest News