welcome to Shanghai Modern Environment Engineering Technique Co., Ltd.

Chinese

Tel:+862159884839

MODERN
INSTRUMENTS

Product Details

Contact Us

  • Products*

  • Name*

  • Company*

  • Email*

  • Phone*

  • Address*

  • Message*

  • Codes*

XD-7600 / 7700Grating Spectrophotometer

Grating Spectrophotometer

Product Number: XD-7600 / 7700

Brand Name:MODERNER

Product Origin: China

Purchasing Heat:475

Standard: CIE No.15, GB / T 3978, GB 2893, GB / T 18833, iso7724 /1, ASTM e1164, din5033 teil7

The instrument has stable performance, accurate color measurement and powerful function. It is widely used in plastic electronics, paint and coating, textile printing and dyeing, printing paper, automobile, medical treatment, cosmetics and food industries, as well as scientific research institutions

Click to see the big picture

Product Details

 Ⅰ.Introduction:

XD-7x series is a grating spectrophotometer that XD company has spent 3 years to design and is developed by XD independent intellectual property righXD . The instrument adopXD 1000 line precision blazed grating as the spectroscopic element, the silicon photocell array with large photosensitive area as the detector, the full spectrum led with high life as the light source, and the optical resolution is less than 10nm in the visible light range.

Under the condition of d/8 geometric optical illumination recommended by CIE, XD-7600/7700 grating spectrophotometer can accurately measure the SCI and SCE reflectance data of samples / fluorescent samples, and also can accurately measure and express various color difference formulas and color indexes in various color spaces. With spectrophotometer XD-7600/7700, it can easily realize the accurate transmission of color and can also be used as the detection equipment of accurate color matching system.

Spectrophotometer XD-7600/7700 is also widely used in the color quality control of various producXD . XD-7600/7700 is equipped with high-end color management software, which is connected to the computer to realize more function expansion. The instrument has stable performance, accurate color measurement and powerful function. It is widely used in plastic electronics, paint and coating, textile printing and dyeing, printing paper, automobile, medical treatment, cosmetics and food industries, as well as scientific research institutions and laboratories etc.



Ⅱ.Features:

XD-7600

1. D / 8 geometric optical structure, conforming to CIE No.15, GB / T 3978, GB 2893, GB / T 18833, iso7724 /1, ASTM e1164, din5033 teil7;
2. Adopt combined LED light source with high life and low power consumption;
3. Customized one 8mm or 4mm aperture ( the flat/ tip measuring aperture can be switched easily, which is suitable for more tested sample)
4. Dual optical path system, the optical resolution in the visible range is less than 10nm, which can measure the SCI and SCE spectrum of the sample at the same time;
5. Accurate spectrum and lab data, used for color matching and accurate color transmission;
6. High hardware configuration: 3.5-inch TFT true color screen, capacitive touch screen, 1000 line blazed grating, silicon photocell array detector with large photosensitive area, etc;
7. USB interface,convenient for expansion of various functions;
8. Super dirt resistant and stable standard white calibration board;
9. Large capacity storage space, which can store more than 20000 pieces of test data
10. 2/10 standard observer's angle, multiple light source modes, multiple surface color systems, meet various standards of chromaticity indicators, and the needs of various customers for color measurement;
11. Camera locating position and Stabilizer cross measurement position;
12.PC software has powerful function expansion;

XD-7700

1. D / 8 geometric optical structure, conforming to CIE No.15, GB / T 3978, GB 2893, GB / T 18833, iso7724 /1, ASTM e1164, din5033 teil7;
2. Adopt combined LED light source with high life and low power consumption, including UV / excluding UV;
3. Switchable 8mm & 4mm aperture( the flat/ tip measuring aperture can be switched easily, which is suitable for more tested sample)
4. Dual optical path system, the optical resolution in the visible range is less than 10nm, which can measure the SCI and SCE spectrum of the sample at the same time;
5. Accurate spectrum and lab data, used for color matching and accurate color transmission;
6. High hardware configuration: 3.5-inch TFT true color screen, capacitive touch screen, 1000 line blazed grating, silicon photocell array detector with large photosensitive area, etc;
7. USB / Bluetooth dual communication mode, wider adaptability;
8. Super dirt resistant and stable standard white calibration board;
9. Large capacity storage space, which can store more than 30000 pieces of test data
10. 2/10 standard observer's angle, multiple light source modes, multiple surface color systems, meet various standards of chromaticity indicators, and the needs of various customers for color measurement;
11. Camera locating position and Stabilizer cross measurement position;
12. PC software has powerful function expansion;

Ⅲ.Main Technical Parameters:

Model

XD-7600

XD-7700

Optical Geometry

Reflect:di:8°,de:8°(diffused illumination, 8-degree viewing angle);

SCI(specular component
included)/SCE (specular component excluded) , excluded UV light source;

SCI (specular component included)/SCE (specular component excluded) ;Include UV / excluded UV light source 

Conforms to CIE No.15,GB/T 3978,GB 2893,GB/T 18833,ISO7724-1,ASTM E1164,DIN5033 Teil7;

Characteristic

Customized one aperture, It is used for precise color measurement and quality control in plastic electronics, paint and ink, textile and garment printing and dyeing, printing, ceramics and other industries, and for fluorescent sample measurement.

double apertures for accurate color analysis and transmission in laboratory. It is used for precise color measurement and quality control in plastic electronics, paint and ink, textile and garment printing and dyeing, printing, ceramics and other industries, and for fluorescent sample measurement.

Integrating
Sphere Size

φ40mm

Light Source

Combined full spectrum LED light source

Combined full spectrum LED light source, UV light source

Spectrophotomet
ric Mode

Flat Grating

Sensor

Silicon photodiode array (double row 40 groups)

Wavelength Range

400~700nm

Wavelength
Interval

10nm

Semiband Width

10nm

Measured
Reflectance

Range

0~200%

Measuring
Aperture

Customized one aperture: MAV:φ8mm/φ10mm;
SAV: φ4mm/φ5mm

MAV: φ8mm/φ10mm;
SAV: φ4mm/φ5mm

Specular
Component

SCI&SCE

Specular
Component

CIE LAB, XYZ, Yxy, LCh, CIE LUV, s-RGB, 0 xy, Munsell(C/2)

CIE LAB, XYZ,Yxy,LCh,CIE LUV, s-RGB, HunterLab, 0 xy, DIN Lab99 Munsell (C/2)

Color Space

△ E*ab,AE*uv,AE*94,AE*cmc(2:1),AE*cmc(1:1),AE*00

AE*ab, AE*uv, AE*94, AE*cmc(2:1), AE*cmc(1:1), AE*00, DIN AE99, AE(Hunter)

Other
Colorimetric

Index

WI(ASTM E313, CIE/ISO,AATCC,Hunter),
YI(ASTM D1925, ASTM 313),

Staining Fastness, Color Fastness, Color Strength, Opacity,

8° Glossiness,

WI(ASTM E313,CIE/ISO,AATCC,Hunter),
YI(ASTM D1925, ASTM 313),

Metamerism Index MI,

Staining Fastness, Color Fastness, Color Strength, Opacity,

8° Glossiness,555 tone classification

Observer Angle

2°/10° 

Illuminant

D65,A,C,D50,F2(CWF),F7(DLF),F10(TPL5),F11(TL84),F12(TL83/U30)

D65, A, C, D50, D55, D75, F1, F2 (CWF), F3, F4, F5, F6, F7 (DLF), F8, F9, F10(TPL5), F11(TL84), F12 (TL83/U30)

Displayed Data

Spectrogram/Values, Samples Chromaticity Values, Color Difference Values/Graph,PASS/FAIL Result, Color Offset

Measuring

Time

About 1.5s (Measure SCI & SCE about 3.2s)

Repeatability

Spectral reflectance: MAV/SCI, Standard deviation within 0. 1% (400 nm to 700 nm: within 0.2%) Chromaticity value: MAV/SCI, within AE*ab 0.04 ( When a white calibration plate is measured 30 times at 5 second intervals after white calibration)

Spectral reflectance: MAV/SCI, Standard deviation within 0. 08% (400 nm to 700 nm: within 0. 18%) Chromaticity value: MAV/SCI, within AE*ab 0.02 (When a white calibration plate is measured 30 times at 5 second intervals after white calibration)

Inter-instrument
Error

MAV/SCI, Within AE*ab0.2 
(Average for 12 BCRA Series II color tiles)

MAV/SCI, Within AE*ab 0.15 (Average for 12 BCRA Series II color tiles)

Measurement
Mode

Single Measurement, Average Measurement(2-99times)

Locating Method

Camera Locating,stabilizer cross position

Dimension

L*W*H =129×76×217mm

Weight

Dimension

Battery

3.7V,5000mAh Li-ion battery, 6000 measuremen XD within 8 hours

Illuminant Life Span

5 years, more than 3 million times measuremen XD

Displayed Data

3.5-inch TFT color LCD, Capacitive Touch Screen

Data Port

USB

Data Port

Data Storage

Standard 1000 Pcs,Sample 20000 Pcs

Standard 1000 Pcs, Sample 30000 Pcs

Language

Simplified Chinese, English, traditional Chinese

Operating Environment

0〜40°C, 0〜85°%RH (no condensing), Altitude < 2000m

Storage
Environment

-20〜50°C, 0〜85°%RH (no condensing)

Standard
Accessory

Power Adapter, User Guide, PC Software(Download from office website), USB cable, White and Black Calibration Cavity, Protective Cover, Wrist strap, One aperture (8mm or 4mm)

Power Adapter, User Guide, PC Software(Download from office website), USB cable, White and Black Calibration Cavity, Protective Cover, Wrist strap, 8mm flat aperture, 8mm tip aperture, 4mm flat aperture, 4mm tip aperture

Notes

The specifications are subject to change without notice.


IV. Ordering Information:

Type

Name

XD-7600

Grating Spectrophotometer

XD-7700


Ⅴ. Documents:

Similar Products

Issued with In-House Calibration Certificate


Latest News